Wood chips firing system UTSD, 25-260 kW

The UTSD is suitable for use in a large single-family house or a block of flats as well as for a community heating system.

inhaltsbild

An overview of the advantages:

  • Optimal air supply
  • 7" Touch Display for an easy and clear boiler control
  • Motors’ reversing
  • Sophisticated combustion chamber geometry
  • Combustion of fuel with moisture content up to M40 is possible
  • Automatic de-ashing system
  • Flexible and therefore ideal positioning of ash containers

Detail wood chips firing system UTSD

inhaltsbild
  1. 7" real-glass touch display
  2. Automatic control
  3. Electrical ignition
  4. Fuel level sensor
  5. Grating position monitoring
  6. Revolving grate
  7. Secondary air injection made from high-quality
    cast stainless steel
  8. Fuel chamber made from shaped bricks
  9. After-burning
  10. Negative pressure monitoring
  11. Safety heat exchanger
  12. Thermowell for thermal flow protection
  13. Automatic heat exchanger cleaning
  14. Stoker screw
  15. Automatic grate ash removal
  16. Transverse screw conveyor for ash
  17. Automatic heat exchanger ash removal
  18. Ash bin
  19. Stoker overtemperature sensor
  20. Stoker
  21. Discharge head with tested backfire flap
  22. Riser screw
  23. Riser screw transfer box
  24. Closed screw channel
  25. Open screw channel with inlet plate
  26. Spring package
  27. Mixing paddle
Boiler type UTSD 45 Nominal capacity kW Operating range kW Weight in Kg
UTSD 45/25 25 7.5 - 25 865
UTSD 45/30 30 9 - 30 865
UTSD 45/35 35 10.5 - 35 865
UTSD 45/40 40 12 - 40 865
UTSD 45/45 45 13.5 - 45 865

Boiler type UTSD 80 Nominal capacity kW Operating range kW Weight in Kg
UTSD 80/35 35 11 - 35 965
UTSD 80/40 40 12 - 40 965
UTSD 80/45 45 13.5 - 45 965
UTSD 80/50 50 15 - 50 965
UTSD 80/60 60 18 - 60 965
UTSD 80/70 70 21 - 70 965
UTSD 80/80 80 24 - 80 965

Boiler type UTSD 140 Nominal capacity kW Operating range kW Weight in Kg
UTSD 140/65 65 19 - 65 1160
UTSD 140/70 70 21 - 70 1160
UTSD 140/80 80 24 - 80 1160
UTSD 140/90 90 27 - 90 1160
UTSD 140/100 100 30 - 100 1160
UTSD 140/110 110 33 - 110 1170
UTSD 140/120 120 36 - 120 1170
UTSD 140/140 140 42 - 140 1170

Boiler type UTSD 240 Nominal capacity kW Operating range kW Weight in Kg
UTSD 240/120 120 33 - 120 2020
UTSD 240/140 140 42 - 140 2020
UTSD 240/160 160 48 - 160 2020
UTSD 240/180 180 54 - 180 2020
UTSD 240/200 200 60 - 200 2020
UTSD 240/220 220 66 - 220 2020
UTSD 240/240 240 72 - 240 2020
UTSD 240/260 260 78 - 260 2020

Nach oben